9.3 Lengthy periods out of use

If the dishwasher is to be out of use for a fairly long period of time, the detergent and rinse aid dispenser devices must be
emptied to prevent crystallisation and damage to the pumps: Remove the intake hoses from the detergent and rinse aid
containers and place them in a container of clean water, then perform a few wash cycles followed by a complete pump-out.
Finally, turn off the master switch, close the water intake valve and leave the door ajar until the interior is completely dry. The
detergent and rinse aid intake hoses must be put back into the containers when the dishwasher is returned to service, taking
care not to swap them over (red hose = detergent, blue hose = rinse aid).

10 TROUBLESHOOTING

In case the pump is not working properly, follow the steps
below:
Empty the dishwasher out using a container and disconnect the
power.
Remove screw A, release tab B and lift it upwards.
Make sure that the covered drain pump impeller can rotate
freely, and that there are no dirt residues, limestone, or pieces
of glass. Do not use tools, screwdrivers, scissors, etc.
PROBLEM
THE INDICATOR LIGHT L1 DOES NOT
LIGHT UP
THE WASHING PROGRAM DOES NOT
START
POOR WASHING RESULTS
POSSIBLE CAUSE
line voltage failure
The dishwasher filling is not over yet.
CLOSE stays on display
Clogged or crusted spray arms holes.
Clogged filter
Insufficient or improper detergent or
rinse aid.
Failing or insufficient use of detergent
or rinse aid: the detergent or rinse aid
cannot be withdrawn from the
dedicated containers.
23
B
POSSIBLE SOLUTION
Verify electricity connection.
Wait for FILL to disappear off the display
If CLOSE stays even with the door closed,
contact the After-Sales Service.
Dismount and clean the spray arms
(10.2 Periodical checks)
Read "cleaning the filters during the day"
Verify detergent type and quantity.
Worn or broken internal tube for
detergent or rinse aid of the peristaltic
pump, to be replaced by the After-Sales
Service.
This ordinary maintenance service is
recommended at least once a year for
the correct functioning of the dosers.