Siemens SINAMICS G120 Operating Instructions Manual page 116

Low voltage converters built-in and wall mounting units with cu230p-2 control units
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Installing
4.5 Connecting the interfaces for the inverter control
Default setting 9: "Standard I/O with MOP"
DO 0: p0730, DO 1: p0731
Motorized potentiometer setpoint after ramp-function generator: r1050
Speed setpoint (main setpoint): p1070[0] = 1050
Designation in the BOP-2: Std MoP
Default setting 12: "Standard I/O with analog setpoint"
Factory setting for inverters with USS, Modbus, BACnet, MS/TP or P1 interface
DO 0: p0730, DO 1:
p0731
Speed setpoint (main setpoint): p1070[0] = 755[0]
Designation in the BOP-2: Std ASP
116
AO 0: p0771[0], AO 1: p0771[1]
AO 0: p0771[0],
DI 0: r0722.0, ..., DI 2: r0722.2
AO 1: p0771[1]
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34257946B AE
DI 0: r0722.0, ..., DI 3: r0722.3
AI 0: r0755[0]
Converter with the CU230P-2 Control Units