Communication
11.23 DR 30 Process state
11.23.2
Current belt load
The current material weight of the loaded belt acting on one unit of the weigh length.
11.23.3
Current belt load in %
Current belt load in % of nominal belt load
11.23.4
Current flow rate
The current material flow rate (belt load x speed).
11.23.5
Current flow rate in %
The current material flow rate (belt load x speed) in % of the nominal flow rate.
11.23.6
Current speed
The current speed used to calculate the material flow rate. The output is made as length per
second.
11.23.7
Current speed in %
The current speed used to calculate the material flow rate. The output is made in % of the
maximum speed.
11.23.8
Current master totalizer (S1)
The total material flow is summed after the start-up and switching-off of service mode.
Resetting the total is only possible using the "Load factory settings" command.
11.23.9
Current main totalizer (S2)
The material flow is saved in a powerfail-proof memory. It can be deleted using the "Log and
delete" command.