Table 6- 2
Labeling
Sig-
Sig+
Sen-
Sen+
Exc-
Exc+
Connect strain gauge load cells with 6 wires
Figure 6-9 Connection of strain gauge load cell(s) with 6-wire system
SIWAREX WT241
Manual, 05/2015, A5E36046748A
Load cell connections on the module
Load cell
Load cell shield
Cable glands shield connection
SIWAREX WT2X1 weighing terminal
Earthing bolt
Function
Measurement cable load cell -
Measurement cable load cell +
Sensor cable load cell -
Sensor cable load cell +
Supply load cell -
Supply load cell +
Connecting
6.3 Connecting the load cells