Dr 31 Process State Extended - Siemens SIWAREX WT241 Manual

Electronic
Table of Contents

Advertisement

Communication

11.24 DR 31 Process state extended

11.24
DR 31 Process state extended
Current states and process values in the scales can be monitored using advanced process
values and process values (DR 30). This data is not required for standard operation of the
scales.
Monitoring selected data during trial operation is extremely useful as it helps you to optimize
parameters.
Procedure
● Read data record DR 31
● Display/analyze the required tags
Table 11- 24 Assignment of data record 31
Variable
Note
Data record num-
Contains no. of data record
ber
Length
Data record length information
Application
Information about which application the
data record belongs to
Version identifier
Information about current data record
version
Unfiltered digit
Unfiltered digit value from A/D convert-
value (Page 159)
er
Filtered digit value
Filtered digit value from A/D converter
(Page 160)
Current load cell
Actual input voltage in mV calculated
signal (mV)
from the input digits
(Page 160)
Current analog
Actual current to be output in mA at the
output (mA)
analog output
(Page 160)
Pulses per belt
Pulses per belt revolution
revolution
(Page 160)
Reserve
Pulses per second
Determined using command "Start belt
at nominal speed
revolution detection"
(Page 160)
Pulses per second
(Page 160)
Reserve
Reserve
Reserve
Reserve
158
Type
L
Rw Default
USHORT
2
r
31
USHORT
2
r
54
USHORT
2
r
104
USHORT
2
r
1
LONG
4
r
0
LONG
4
r
0
LONG
4
r
0
USHORT
2
r
0
LONG
4
r
0
FLOAT
4
r
0
FLOAT
4
r
0
USHORT
2
r
0
USHORT
2
r
0
USHORT
2
r
0
M
Max. Register
i
n
.
- -
3300
- -
3301
- -
3302
1 6563
3303
5
- -
3304
- -
3306
- -
3308
0 6553
3310
5
0
3312
0
3314
3316
0 6553
3318
5
0 6553
3319
5
0 6553
3320
5
SIWAREX WT241