Menu 1.4 Additional Parameters - Siemens SIWAREX WT241 Manual

Electronic
Table of Contents

Advertisement

Scale parameters and functions of the belt scale
8.5 Menu 1.3 Limits
1.3.2 Limits 2 / 2
Minimum load for
totalizing
Maximum positive
zero offset
Maximum negative
zero offset
8.6

Menu 1.4 Additional parameters

1.4.1 Calculator & stopwatch
1.4.2 Messaging setting
2000 Technological
message
2002 Trace over-
loaded
2003 Zero setting
aborted
3001 Totalizers
disturbed
2004 Trace aborted
3002 Calibration
aborted
1.4.3 Incline angle
66
Totalizing is not carried out below this value. The specification is made
in % of the belt load. If "0" is specified, totalizing is bidirectional.
Zeroing sets the current weight of the scale and the belt load to zero.
The specification is made in % of the nominal belt load. The range re-
fers to the original zero point of the last calibration.
In the case of sales for legal trade operation, the maximum zero offset is
4%.
A calculator and a stopwatch for use when commissioning the scale or
maintaining it.
This menu gives the option to blank messages being produced by the
weighing electronic. In case displaying a message is not wanted, chose
"suppress message" for the applicable message.
Group message, at least one technology error exists
The set recording rate for trace function cannot be processed. Set a
slower recording rate.
The zeroing procedure has been canceled. Possible causes: violation of
zeroing limits.
Fault occurred during totalizing.
The trace recording has been cancelled. Possible causes: trace memory
full and not declared as ring memory.
Current calibration procedure has been aborted. Possible causes: non-
plausible values have been determined during the command.
Input of the angle is provided for belt scales where the inclination of the belt
can be changed during operation. Calculation of the current belt load is cor-
rected by entering the current angle.
The input is unnecessary if the inclination is always constant: the influence
of the constant angle is compensated or automatically taken into considera-
tion during the calibration with weights or test chain.