Siemens SIWAREX WT241 Manual page 121

Electronic
Table of Contents

Advertisement

Variable
Note
Delay for
Delay for output of status display for
belt speed
belt speed (in ms)
limits
(Page 123)
Minimum
Min. belt load for status display 'Mini-
belt load
mum belt load violated' in % of nominal
(Page 123)
belt load
Maximum
Max. belt load for status display 'Maxi-
belt load
mum belt load violated' in % of nominal
(Page 123)
belt load
Delay for
Delay for output of status display for
belt load
belt load (in ms)
limits
(Page 123)
Reserve
Medium
Min. belt load required to start totalizing.
load for
Specification in % of nominal belt load
totalizing
(Page 123)
Reserve
Frequency
Low-pass filter - filtering of weight limit
low pass
frequency
filter
0: filter switched off
weight/belt
Range fg: 0.05 ... 50 Hz
load/belt
speed
(Page 124)
Order no
Filter number 2*(1...5)
low pass
filter
(Page 124)
Reserve 2
Reserve
Frequency
Low-pass filter - filtering of speed limit
low pass
frequency
filter
0: filter switched off
weight/belt
fg: 0.05 ... 50 Hz
load/belt
speed
(Page 124)
Order no
Filter number 2*(1...5)
low pass
filter
(Page 124)
Reserve
Reserve
Depth av-
Depth of average filter for weight meas-
erage filter
urement (n x 10 ms)
flow rate
(Page 124)
SIWAREX WT241
Manual, 05/2015, A5E36046748Aa
Type
L
Rw
LONG
4
rw
FLOAT
4
rw
FLOAT
4
rw
LONG
4
rw
LONG
4
rw
FLOAT
4
rw
FLOAT
4
rw
USHORT
2
rw
FLOAT
4
rw
FLOAT
4
rw
SHORT
2
rw
FLOAT
4
rw
USHORT
2
rw
USHORT
2
rw
Communication
11.9 DR 6 Limits
De-
Min.
Max.
fault
1
0
5
0
100
100
0
200
1
0
1
0
0
0
0.5
0
50
4
1
5
0
0
0
0
50
4
1
5
0
0
0
0
0
0
0
0
0
Register
1284
1286
1288
1290
1292
1298
1300
1301
1302
1304
1305
1307
1308
121