Commissioning
7.3 Commissioning via Quick Start routine
A percentage belt load factor and a percentage speed factor are determined. These two
values together with the determined nominal speed (→ Determination of current belt speed
(belt empty) (Page 49)) then form a characteristic.
Figure 7-8
Prerequisites for determination of the characteristic are:
● Speed calculation has been carried out with empty belt
● Successful zero calibration
● Successful span calibration
If these conditions have been fulfilled, move on to menu item 1.2.1.3.
50
Speed characteristic without sensor
SIWAREX WT241
Manual, 05/2015, A5E36046748A