Servicing The Air Cleaner - Hobart 60CU20 Operation And Maintenance Manual With Illustrated Parts List

60 kva, 3 phase, 115/200 volt, 400 hz. generator set. series 500062
Table of Contents

Advertisement

OM-2226 / Operation and Maintenance Manual
60CU20 / Series 500062 / 400 Hz. Generator Set

3) Servicing the Air Cleaner

A definite time schedule for cleaning or changing the air cleaner cannot be determined because of
varying operating conditions. Unfasten the three metal latches on the end of the air cleaner housing to
access the air cleaner filter. It may be inspected either at prescribed service intervals or at any time
deemed necessary.
Replacement air filter part
number:
Hobart: 290941
Inspect regularly.
Replace when the fault
code meter indicates an
"Air" code.
a) Inspecting the Air Cleaner
(1) Make periodic checks of air cleaner inlet screen for obstructions. If any obstructions are present,
remove them.
(2) Check outlet connection for proper seal.
b) Changing the Air Filter
(1) Lift the latch and rotate the back cover to the unlocked position (counterclockwise as viewed from
the rear). The cover has padlock symbols to show the locked and unlocked positions.
(2) Remove the end cover of housing.
(3) Pull out air filter elements and replace.
(4) Replace end cover on housing, making certain that the filter is centered in the housing.
(5) Replace the end cover and rotate it to the locked position.
May 2, 2013
Figure 3: Air Cleaner Assembly
Chapter 2-2
Page 6

Hide quick links: