Solution
To resolve the problem:
1.
Verify that the Data bits field is set to 8 for the console terminal. If the Data bits field is set to 5
or 6, the console terminal will display garbled characters.
2.
Verify that the Bits per second field is set to 9600 bps. An incorrect Bits per second might
also cause the configuration terminal to display garbled characters.
3.
If the problem persists, contact Hewlett Packard Enterprise Support.
No response from the serial port
Symptom
The serial port gives no response.
Solution
To resolve the problem:
1.
Verify that the serial port settings are correct.
2.
If the problem persists, contact Hewlett Packard Enterprise Support.
For more information about the serial port settings, see
Dealing with password loss
CAUTION:
Dealing with console login password loss and user privilege level password loss from BootWare
menus is disruptive.
How to deal with console login password loss and user privilege level password loss depends on the
state of password recovery capability (see
user access to the device configuration and SDRAM from BootWare menus.
•
If password recovery capability is enabled, a console user can access the device configuration
without authentication and configure new passwords.
•
If password recovery capability is disabled, a console user must restore the factory-default
configuration before configuring new passwords. Restoring the factory-default configuration
deletes the main and backup next-startup configuration files.
To enhance system security, disable password recovery capability.
"Configuring basic
Figure
62). Password recovery capability controls console
66
settings."