Table 6 Router dimensions and rack requirements
Model
HSR6802
HSR6804
HSR6808
NOTE:
The signal cables and power cords are routed through the front of the chassis. If you use power
cords that has a conductor cross-section area of a minimum of 16 sq mm (0.02 sq in), leave more
space between the front rack posts and the front door as appropriate.

Power supply

Make sure the power supply system at the installation site is stable and meets the requirements
of the power supplies, including the rated input voltage.
Select power supplies based on the power consumption of the cards and fan trays. For more
information about system power consumption and technical specifications of power supplies,
see
"Appendix A Chassis views and technical

Installation accessories

Table 7 Installation accessories
Product code
5185-8627
Chassis dimensions
Height—220 mm (8.66 in)/5 RU
Width—436 mm (17.17 in)
Depth—576 mm (22.68 in)
480 mm (18.90 in) for the chassis
95 mm (3.74 in) for the cable
management brackets at the chassis
front
11 mm (0.43 in) for the grounding
screw at the chassis rear
Height—308 mm (12.13 in)/7 RU
Width—436 mm (17.17 in)
Depth—576 mm (22.68 in)
480 mm (18.90 in) for the chassis
95 mm (3.74 in) for the cable
management brackets at the chassis
front
11 mm (0.43 in) for the grounding
screw at the chassis rear
Height—886 mm (34.89 in)/20 RU
Width—436 mm (17.17 in)
Depth—591 mm (23.27 in)
480 mm (18.90 in) for the chassis
102 mm (4.02 in) for the cable
management brackets at the chassis
front
11 mm (0.43 in) for the grounding
screw at the chassis rear
Item
Console cable
Rack requirements
A minimum of 95 mm (3.74 in)
between the front rack posts and the
front door.
A minimum of 481 mm (18.94 in)
between the front rack posts and the
rear door.
As a best practice, use a rack a
minimum of 0.8 m (2.62 ft) in depth.
A minimum of 95 mm (3.74 in)
between the front rack posts and the
front door.
A minimum of 481 mm (18.94 in)
between the front rack posts and the
rear door.
As a best practice, use a rack a
minimum of 0.8 m (2.62 ft) in depth.
A minimum of 102 mm (4.02 in)
between the front rack posts and the
front door.
A minimum of 490 mm (19.29 in)
between the front rack posts and the
rear door.
As a best practice, use a rack a
minimum of 0.8 m (2.62 ft) in depth.
specifications".