Palm Led Is Steady On; Lpu Failures; Run Led Is Off - HP FlexNetwork HSR6802 Installation Manual

Flexnetwork hsr6800 series
Table of Contents

Advertisement

PALM LED is steady on

Symptom
The PALM LED for the MPU is steady on. For more information about MPU LEDs, see
Solution
To resolve the problem:
1.
Verify that the power supply and power consumption match.
For example, if an HSR6808 is installed with a 650 W power supply but two SAP-48GBE
modules, the power available is not sufficient for the whole power consumption and one SAP
module cannot be powered on.
2.
Verify that the router has one type of power supplies installed: AC power supplies or DC power
supplies.
3.
If the problem persists, contact Hewlett Packard Enterprise Support.
Table 21 MPU LEDs
LED
RUN (green)
ACT (green)
PALM (red)
ALM (red)

LPU failures

RUN LED is off

Symptom
The RUN LED for the LPU is off.
Solution
To resolve the problem:
1.
Verify that the router is powered on.
2.
Verify that the LPU is correctly inserted in a slot.
3.
Verify that the system power is sufficient. If the system power is insufficient, the system displays
the following information:
Status
Off
Flashing slowly at 1 Hz
Flashing fast at 8 Hz
Off
Steady on
Off
Steady on
Off
Steady on
Flashing fast at 8 Hz
Description
No power is provided or the MPU is faulty.
The MPU is operating correctly.
The MPU is loading system software images. To avoid
MPU damage, do not power off the router or hot-swap
the MPU.
The MPU is not operating.
The MPU is in standby state.
The MPU is in active state.
The power supply is operating correctly.
The power for use is not sufficient, or power supplies of
different specifications are inserted.
The system is operating correctly without any alarm.
The system is faulty. You must view the system logs.
The system is seriously faulty. An immediate action is
needed.