Hardware installation
Two screw holes each front and rear
3
2 x M5
Figure 5: Fit the left telescopic rail in the PRIMECENTER/DataCenter Rack
Ê Place the left support system (1) in the support bracket (a) with lug (b) in the
middle square catch.
Ê Clamp the left-hand rail (2) between the front left support upright (c) and the
support bracket (a) by pressing the rail together, positioning the rail on the
front support upright, and releasing them again. The rail automatically
adjusts to the rack depth.
Ê Attach the left support system with two M5 centering fixtures (3) each on the
left front support upright (c) and the rear support bracket (a).
Ê Repeat the above steps with the right-hand support system (it is secured to
the front and rear right support uprights).
Ê Fit the cage nuts for securing the server in the corresponding catch on the
right and left support uprights.
Ê Fit the PRIMECENTER/DataCenter Rack cable management as described
in the technical manual for the rack.
Ê Insert the server (see section
Ê Route the cables once the server has been inserted, as described in the
Technical Manual for the rack.
TX300 S4
c
2
"Inserting the server" on page
Operating manual
Installing/removing the rack model
a
1
b
3
2 x M5
58).
49