TP Connector and Cable Recommendations

The TIA/EIA T 568B wiring standard is detailed in figure 4. Use this standard to terminate
the TP cable with RJ-45 connectors.
Side
Figure 4.
ATTENTION:
Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201
cable to link the switching transmitter and receiver.
N'utilisez pas le câble AV Skew-Free UTP version améliorée UTP23SF d'Extron ou
le câble STP201 pour relier les produits XTP avec les émetteurs ou les récepteurs
DTP.
Supported cables
DTP T SW4 HD 4K is compatible with shielded twisted pair (STP) and unshielded twisted
pair (U/UTP) cable. However, Extron strongly recommends that you use STP cable to
achieve best performance.
Cable recommendations
Extron recommends using the following practices to achieve full transmission distances up
to 330 feet (100 meters) and reduce transmission errors.
Use the following Extron XTP DTP 24 STP cables and DTP 24 connectors for the best
performance:
XTP DTP 24/1000
XTP DTP 24P/1000 Plenum 1000 feet (305 meters) spool
XTP DTP 24 Plug
If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid
conductor, STP cable with a minimum bandwidth of 400 MHz.
Terminate cables with shielded connectors to the TIA/EIA-T568B standard.
Use no more than two pass-through points, which may include patch points, punch
down connectors, couplers, and power injectors. If these pass-through points are
required, use Category 6 or 6a shielded couplers and punch down connectors.
NOTES: When using TP cable in bundles or conduits, consider the following:
Do not exceed 40% fill capacity in conduits.
Do not comb the cable for the first 65 feet (20 meters), where cables are
straightened, aligned, and secured in tight bundles.
Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners.
Separate twisted pair cables from AC power cables.
Pins:
RJ-45
1 2 3 4 5 6 7 8
Connector
TIA/EIA T
568B
Pin
Wire color
1
White-orange
2
Orange
3
White-green
4
Blue
5
White-blue
6
Green
Insert
7
White-brown
Twisted
8
Brown
Pair Wires
TP Cable Termination
Non-Plenum 1000 feet (305 meters) spool 22-236-03
Package of 10
22-235-03
101-005-02