In the Contact/Tally Mode 1 diagram, the IPL Pro S3 controls all six ports, as it monitors the
status of the ports through the RS-232 driver. The IPL also controls the display, sending the
command to power it On and Off.
Operation of Contact/Tally Mode 1:
The Extron IPL Pro S3 is configured with GCP (see
for Contact/Tally Modes
and display via Extron RS-232 drivers, using Actions and Conditions configured to
control the devices.
When contact ports 1, 2, or 3 are momentarily closed (shorted) with the Extron
Show Me cables, a command to switch video input is sent from the IPL to the switcher
via RS-232 drivers to switch to the appropriate input.
The CCR 30 is wired to contact/tally ports 4 and 5 to send commands to power the
display ON and OFF. The IPL monitors the status of ports 4 and 5 via the RS-232 driver.
The CCR 30 power
When the contact pin of port 4 is closed (shorted), the IPL receives an
unsolicited response from the switcher via the RS-232 driver.
The IPL sends a command through the switcher to the display to power
The IPL sends a command to close tally pin 4, which lights the LED button for
power
.
ON
The IPL also sends a command to open tally pin 5, which turns off the LED
button for power
The CCR 30 power
When the contact pin of port 5 is closed (shorted), the IPL receives an
unsolicited response from the switcher through the RS-232 driver.
The IPL sends a command through the switcher to the display to power
The IPL sends a command to close tally pin 5, which lights the LED button for
power
.
OFF
The IPL also sends a command to open tally pin 4, which turns off the LED
button for power
The CCR 30 is wired to contact/tally port 6 for muting:
The
MUTE ON/OFF
NOTE: The
MUTE ON/OFF
The first compression of the button latches contact pin 6 closed, sending the IPL an
unsolicited response from the switcher through the RS-232 driver.
The IPL then sends a command to close tally pin 6, to light the LED button for
.
ON/OFF
The IPL also sends an RS-232 command through the switcher to the display to
mute
.
ON
The second compression of the button latches contact pin 6 open, sending the IPL
an unsolicited response from the switcher through the RS-232 driver.
The IPL then sends a command to open tally pin 6, to turn off the LED button for
.
MUTE ON/OFF
The IPL also sends an RS-232 command through the switcher to the display to
mute
.
OFF
on page 23) to monitor and control the switcher, CCR 30,
button is wired to contact/tally 4:
ON
.
OFF
button is wired to contact/tally 5:
OFF
.
ON
button does not affect the power buttons.
button is configured for latching operation.
DTP T SW4 HD 4K • Operation
Control Processor Configuration
.
ON
.
OFF
MUTE
18