TP Connector and Cable Recommendations

See figure 5 for the TIA/EIA T 568B wiring standard. Use this standard to terminate the TP
cable with a RJ-45 connector.
Side
Figure 5.
ATTENTION:
Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201
cable to link the XTP products or with DTP transmitters or receivers. The
DTP2 T 212 does not work properly with these cables.
N'utilisez pas le câble audiovisuel Skew Free UTP version améliorée UTP23SF-4
Extron ou le câble STP201 pour relier l'émetteur et le récepteur/sélecteur. Le
DTP2 T 212 ne fonctionne pas correctement avec ces câbles.
Supported cables
The DTP2 T 212 switcher is compatible with shielded twisted pair (STP) and unshielded
twisted pair (U/UTP) cable. However, Extron strongly recommends that you use STP cable
to achieve best performance.
Cable recommendations
Extron recommends using the following practices to achieve full transmission distances up
to 230 feet (70 meters) or 330 feet (100 meters) and reduce transmission errors.
Use the following Extron XTP DTP 24 STP cables and DTP 24 connectors for the best
performance:
XTP DTP 24/1000
XTP DTP 24P/1000 Plenum 1000 feet (305 meters) spool
XTP DTP 24 Plug
If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid
conductor, STP cable with a minimum bandwidth of 400 MHz.
Terminate cables with shielded connectors to the TIA/EIA-T568B standard.
Use no more than two pass-through points, which may include patch points, punch
down connectors, couplers, and power injectors. If these pass-through points are
required, use Category 6 or 6a shielded couplers and punch down connectors.
NOTE: When using TP cable in bundles or conduits, consider the following:
Do not exceed 40% fill capacity in conduits.
Do not comb the cable for the first 20 meters, where cables are straightened,
aligned, and secured in tight bundles.
Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners.
Separate twisted pair cables from AC power cables.
Pins:
RJ-45
1 2 3 4 5 6 7 8
Connector
TIA/EIA T
568B
Pin
Wire color
1
White-orange
Orange
2
3
White-green
4
Blue
5
White-blue
6
Green
Insert
7
White-brown
Twisted
8
Brown
Pair Wires
TP Cable Termination
Non-Plenum 1000 feet (305 meters) spool
Package of 10
DTP2 T 212 • Installation
11