Operator's Manual
FUNCTION TESTS
Test the Horn
14 Pull out the red Emergency Stop button to the
on position.
15 Push the horn button.
Result: The horn should sound.
Test the Foot Switch
16 Do not press down the foot switch. Activate
each machine function.
Result: The machine functions should not
operate.
Test Machine Functions
17 Press down the foot switch.
18 Activate each machine function toggle switch.
Result: All boom and platform functions should
operate through a full cycle.
Note: Control the speed of boom functions by
adjusting the boom function speed controller. Drive
and steer functions are not affected by the boom
function speed controller.
20
Test the Steering
19 Press down the foot switch.
20 Depress the thumb rocker switch on top of the
drive control handle in the direction identified by
the blue triangle on the control panel.
Result: The steer wheels should turn in the
direction that the blue triangles point on the
drive chassis.
21 Depress the thumb rocker switch in the direction
identified by the yellow triangle on the control
panel.
Result: The steer wheels should turn in the
direction that the yellow triangles point on the
drive chassis.
Z-34/22 • Z-34/22N
Sixth Edition • First Printing
Part No. 1258814