8. TROUBLESHOOTING
Note 1. Leave for about 30 minutes of cooling time after removing the cause of occurrence.
2. The following shows three stop methods of DB, EDB, and SD.
3. This is applicable when [Pr. PA04] is set to the initial value. The stop method of SD can be changed to DB
DB: Dynamic brake stop (For a servo amplifier without the dynamic brake, the servo motor coasts.)
EDB: Electronic dynamic brake stop (available with specified servo motors)
Refer to the following table for the specified servo motors. The stop method for other than the
specified servo motors is DB.
Setting [Pr. PF09] to "(_ _ _ 3)" enables the electronic dynamic brake.
Series
HG-KN
HG-KN053/HG-KN13/HG-KN23/HG-KN43
HG-SN
HG-SN52
SD: Forced stop deceleration
using [Pr. PA04].
Servo motor
8 - 5