Mitsubishi MR-JE-10A Instruction Manual page 231

Servo amplifiers
Table of Contents

Advertisement

7. SPECIAL ADJUSTMENT FUNCTIONS
(1) Instantaneous power failure time > [Pr. PF25 Instantaneous power failure tough drive - detection time]
The alarm occurs when the instantaneous power failure time exceeds [Pr. PF25 Instantaneous power
failure tough drive - detection time].
MTTR (During tough drive) turns on after the instantaneous power failure is detected.
MBR (Electromagnetic brake interlock) turns off when the alarm occurs.
Power supply
Bus voltage
Undervoltage level
(158 V DC)
ALM
(Malfunction)
WNG
(Warning)
MTTR
(During tough drive)
MBR
(Electromagnetic
brake interlock)
Base circuit
Instantaneous power failure time
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
7 - 24