Dell S4048–ON Configuration Manual page 336

Hide thumbs Also See for S4048–ON:
Table of Contents

Advertisement

Example of Configuring the ENode Server-Facing Port
Dell(conf)# interface tengigabitethernet 1/1
Dell(conf-if-te-1/1)# portmode hybrid
Dell(conf-if-te-1/1)# switchport
Dell(conf-if-te-1/1)# protocol lldp
Dell(conf-if-te-1/1-lldp)# dcbx port-role auto-downstream
NOTE:
A port is enabled by default for bridge-ENode links.
Example of Configuring the FCF-Facing Port
Dell(conf)# interface tengigabitethernet 1/5
Dell(conf-if-te-1/5)# portmode hybrid
Dell(conf-if-te-1/5)# switchport
Dell(conf-if-te-1/5)# fip-snooping port-mode fcf
Dell(conf-if-te-1/5)# protocol lldp
Dell(conf-if-te-1/5-lldp)# dcbx port-role auto-upstream
Example of Configuring FIP Snooping Ports as Tagged Members of the FCoE VLAN
Dell(conf)# interface vlan 10
Dell(conf-if-vl-10)# tagged tengigabitethernet 1/1
Dell(conf-if-vl-10)# tagged tengigabitethernet 1/5
Dell(conf-if-te-1/1)# no shut
Dell(conf-if-te-1/5)# no shut
Dell(conf-if-vl-10)# no shut
After FIP packets are exchanged between the ENode and the switch, a FIP snooping session is established. ACLs are dynamically
generated for FIP snooping on the FIP snooping bridge/switch.
336
FIP Snooping

Advertisement