Mib Support For Power Monitoring; Mib Support To Display The Available Memory Size On Flash; Viewing The Available Flash Memory Size - Dell S4048–ON Configuration Manual

Hide thumbs Also See for S4048–ON:
Table of Contents

Advertisement

The following command shows how to get a MIB object value using the object name.
> snmpget -v 2c -c private -m ./f10-copy-config.mib 10.11.131.140 copyTimeCompleted.110
FTOS-COPY-CONFIG-MIB::copyTimeCompleted.110 = Timeticks: (1179831) 3:16:38.31
The following command shows how to get a MIB object value using OID.
> snmpget -v 2c -c private 10.11.131.140 .1.3.6.1.4.1.6027.3.5.1.1.1.1.13.110
SNMPv2-SMI::enterprises.6027.3.5.1.1.1.1.13.110 = Timeticks: (1179831) 3:16:38.31

MIB Support for Power Monitoring

Dell Networking provides MIB objects to display the information for Power Monitoring. The OIDs specific to Power Monitoring are
appended to the DellITaMIbs. There are three separate DellITaMIbs available to display the current input power, average input power and
average input-power start time. These statistics can also be obtained by using the CLI command:
lists the related MIB objects, OID and description for the same:
Table 93. MIB Objects to Display the Information for Power Monitoring
MIB Object
envMonSupplyCurrentPower
envMonSupplyAveragePower
envMonSupplyAvgStartTime
SNMP Walk Example Output
snmpwalk -v 2c -c public 10.16.131.156 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.5
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.5.11 = INTEGER: 48
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.5.12 = INTEGER: 40
snmpwalk -v 2c -c public 10.16.131.156 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.6
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.6.11 = INTEGER: 31
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.6.12 = INTEGER: 26
snmpwalk -v 2c -c public 10.16.131.156 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.7
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.7.11 = STRING: "04/25/2017-18:32"
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.7.12 = STRING: "04/25/2017-18:32"
MIB Support to Display the Available Memory Size on
Flash
Dell Networking provides more MIB objects to display the available memory size on flash memory. The following table lists the MIB object
that contains the available memory size on flash memory.
Table 94. MIB Objects for Displaying the Available Memory Size on Flash via SNMP
MIB Object
chStackUnitFlashUsageUtil
The chStackUnitUtilTable MIB table contains the chStackUnitFlashUsageUtil MIB object which contains the flash memory usage percent.
The chStackUnitUtilTable is located in f10SSerChassisMib MIB.

Viewing the Available Flash Memory Size

876
Simple Network Management Protocol (SNMP)
OID
1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.5
1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.6
1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.7
OID
1.3.6.1.4.1.6027.3.10.1.2.9.1.6
show environment . The following table
Description
Displays per PSU input power (current
configuration).
Displays average input power.
Displays average input-power start time.
Description
Contains flash memory usage in percentage.

Advertisement