[Equipment Type No.]: Keep the default setting.
[Subsystem]: When sharing the sensor data through HUB-3000: Set the value.
Setting range: "A" to "Z". Do not share the sensor data: Keep the default setting
("---").
4. Click [No.1 Sensor Adapter] on the menu bar.
Basic Setting
Basic Setting
Own Ship Setting
Own Ship Setting
The sensor adapter consists of four sub units: Serial Input, Digital Input, and An-
alog Input.
5. Click [Serial Input]. There are eight ports in the Serial Input. "Serial 01" to "Serial
04" can input at 38,400 bps for the AIS and Gyro.
The connector no. on the VR-7000 board and the corresponding serial port no. are
shown below.
Connector No.
J4
J5
J6
J7
Installation Parameters
Installation Parameters
CCRS
CCRS
Serial Port No.
Serial 01
Serial 02
Serial 03
Serial 04
7. SETTING FOR SENSOR ADAPTER
TCS
TCS
Connector No.
Serial Port No.
Serial 05
J8
Serial 06
Serial 07
J9
Serial 08
AMS
AMS