2. SOFTWARE CONFIGURATION
4) Enter unit for the values in [Engineering Value Unit].
In the illustration on the preceding page, the [Engineering Value Unit] is set to
degrees (deg). The [Calibration Point 1] is -10V, corresponding to 0 degrees,
and [Calibration Point 2] is 10V corresponding to 30 degrees. This is set
corresponding to the connected analog sensor.
Click the [Apply] button to apply values. When this is done, the [New
Engineering Value] of 29.835V, corresponding to the input voltage of 9.89V, is
displayed at the bottom of the dialog box. Whenever the input value is
changed this value also changes. Check that the [New Engineering Value] is
within an appropriate range.
Another method of entry is to observe the [Voltage] (or [Current]) field on the
top line and click the [Hold] button of Point1 when an appropriate value is
displayed. Do this again for Point2. Click the [OK] Button.
4. Click the [Set] button to finish. Be sure to do this before moving another to
channel.
5. Repeat steps 1-4 to set up all channels.
When using Config Manager with Tabs:
1. From the [Maintenance] menu, click [VDR Config Management].
2. Click the [Upload] button to record to the VDR memory.
3. Click the [Write] button to record to DRU, Long Term Device, and CF.
Description of items in the Settings window
[CH Active Set] button: Click to show the [CH Active Setting] dialog box. Collective set-
ting is done from this box.
[Active]: Put check in check box to make channel active.
[Brand]: Enter brand name.*
[Type No.]: Set type no. (equipment name).*
[Interface] (JB or SA1-8): Type of Interface, [Junction Box] or [Sensor Adapter]. The
number of channels
[Check]: Do equipment check.*
[Data Name]: Enter data name.*
[Data Type]: Analog Data type (0~10V, -10~10v, 4~20mV)
[Sampling Rate]: Display sampling rate.
[Calibration Active]: Disable and enable analog calibration.
[Calibration Point 1]#: Enter calibration point 1.
[Calibration Point 1 Value]#: Enter calibration point 1 value.
[Calibration Point 2#]: Enter calibration point 2.
[Calibration Point 2 Value]#: Enter calibration point 2 value.
[Engineering Value Unit]#: Enter engineering value unit.
Note: For #-marked fields, the values set in the [Analog Calibration] dialog box are dis-
played.
[Equipment Category]: Set equipment category.*
[Board Name]: Enter board names where channels are present.*
[Note]: Enter remarks. (Entry optional.)
* Enter these items for easy identification of equipment.
Note: Channels are assigned according to the presence or absence of Junction
Box(es), and the Junction Box count is set on the [System] tab.