Furuno VR-7000 Instruction Manual page 24

Vdr maintenance viewer
Hide thumbs Also See for VR-7000:
Table of Contents

Advertisement

2. SOFTWARE CONFIGURATION
Description of the buttons in the Setting window
[Set]: Save edited data.
[Capture]: Show received serial data in the [Serial] window. After setting the channels,
click this button to check if serial data is received. If not received, lower the baud rate.
[Select Equipment]: Select equipment settings (saved to the database) to reflect in
channel.
[Reflect Equipment]: Save the equipment setting data to the database.
[Check]: Check all channels. The results are shown as [OK] or [NG] (No Good), in the
[Information] window.
[P-sentence]: Show the [P-sentence definition] dialog box.
[Field No].: Show the field no.
[Name]: Set the name of the P-sentence.
[Detail]: Set the details of the P-sentence.
[Set] button: Reflect settings to the server.
[Cancel] button: Restore settings to previous state.
Description of the items in the Setting window
[Active]: Check to make channel active.*
[Brand]: Enter brand name.
[Type No.]: (Equipment Name)*: Set type no. (equipment name).
[Check]: Do equipment check.*
[Data Name]: Enter data name.*
[Data Type]: Enter data type.
[Baud Rate]: Set baud rate (Available for SI01 to SI08).
[Data Bits]: Set number of bits (Available for SI01 to SI08).
[Parity Bit]: Set parity bit (Available for SI01 to SI08).
[Stop Bit]: Set stop bit (Available for SI01 to SI08).
[Source Checksum]: Check to use checksum for GPS source.
[Time out]: Set time out.
[Equipment Category]: Set equipment category.*
[Board Name]: Board name.*
[Note]: Enter remarks. (Entry optional.)
*Enter these items for easy identification of equipment.