Digital Signal - Furuno VR-7000 Instruction Manual

Vdr maintenance viewer
Hide thumbs Also See for VR-7000:
Table of Contents

Advertisement

2.5

Digital Signal

Analog signals are input via Sensor Adapter MC-3010A or the Interface Unit IF-8530.
The channel number depends on connected equipment. See the table below.
Channels are assigned according absence or presence of junction box(es). The num-
ber of junction boxes is set on [System] tab.
JB (Yes/No)
Yes
No
How to set the digital channels
1. Click the [Digital] tab.
2. Select a channel from the [Information] window. Set up the digital signal from the
[Setting] window, referring to the descriptions in this section.
Note: In the default setting, there is no preset data when the [Select Equipment]
button is clicked. In the case that the setup was completed on another ship and
saved using [Reflect Equipment], import the data by clicking [Select Equipment]
and choosing the saved data.
3. Do the following to set the digital signal to each 64 channel group:
1) Click the [Calibration] button in the [Setting] window.
2) Check the [Active] field of the channel group being set.
3) Enter the status in columns 0 and 1 of that group.
4) Click the [OK] Button.
JB CH
Sensor Adapter 1 CH
CH1 - CH646
-
2. SOFTWARE CONFIGURATION
Sensor Adapter 2 CH
CH65 - CH144
CH1 - CH80
CH145 - CH224
CH81 - CH161
2-11

Hide quick links:

Advertisement

Table of Contents
loading