Page 1
INSTRUCTION MANUAL DATA EXTRACTION PROCEDURE VR-7000/VR-7000S Model DO NOT OPEN Important material for the exclusive use by Investigating Authorities www.furuno.com All brand and product names are trademarks, registered trademarks or service marks of their respective holders.
Page 3
ABOUT THIS MANUAL Overview This manual provides the instructions for extracting the data from the DCU and DRU with the Live Player V5. About trademarks • Windows, Internet Explorer, Microsoft Visual C++, and DirectX are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. •...
TABLE OF CONTENTS INSTALLATION ......................1 1.1 Installable PC ........................ 1 1.2 How to Install the Live Player V5 and Set Up the PC ........... 1 ® 1.2.1 Windows 7 ......................2 ® 1.2.2 Windows 8.1 ......................3 ® 1.2.3 Windows 10 ......................
The Live Player V5 is a software program that installs in a PC, and functions to monitor and play- back the data collected in the VR-7000/7000S’s DRU, Long Term Device of the Data Collecting Unit (DCU). Install the Live Player V5 in a PC using the program CD (supplied).
Install the software 1. Insert the supplied program CD into the CD drive. 2. Run "view.exe" on the program CD to show the [Setup-VR-7000] dialog box. 3. Click the [Next] button. 4. Confirm that the install location is "C:\Program Files*\FURUNO" then click the [Next] button.
Install the software 1. Insert the supplied program CD into the CD drive. 2. Run "view.exe" on the program CD to show the [Setup-VR-7000] dialog box. 3. Click the [Next] button. 4. Confirm that the install location is "C:\Program Files*\FURUNO" then click the [Next] button.
Install the software 1. Insert the supplied program CD into the CD drive. 2. Run "view.exe" on the program CD to show the [Setup-VR-7000] dialog box. 3. Click the [Next] button. 4. Confirm that the install location is “C:\Program Files(x86)\FURUNO” then click the [Next] but- ton.
8.1: [Start] screen > Right click a blank part of screen then select [All Apps] > click [VR-7000 Previous Version] > [Live Player V5 OLD (01.10)] ® • Windows 10: [Start] menu > [All Apps] > [VR-7000 Previous Version] > [Live Player V5 OLD (01.10)]...
DATA EXTRACTION FROM FIXED No Damage to the DCU or Cables 1. Make the connections shown below. Remote alarm panel (RAP) J309 (RAP) port: Connect the remote alarm panel (RAP). TTYCSLA-4 cable J311 (DRU POWER) port: Connect the power cable of Fixed DRU the fixed DRU.
2. DATA EXTRACTION FROM FIXED DRU The signals of the terminal board in the fixed DRU are shown below. SOCKET 1 SOCKET 5 SOCKET 6 SOCKET 10 Terminal board in the fixed DRU (front view) Socket number Signal Cable 24 V Power cable 24 V No connection...
2. DATA EXTRACTION FROM FIXED DRU How to Remove the Capsule from the Fixed DRU When you can not remove the entire fixed DRU due to damage, remove the capsule from the fixed DRU for data extraction as follows: Note: In an emergency situation, priority must be given to evacuation of personnel. Remove the fixed DRU only when there is enough time to do so.
DATA EXTRACTION FROM FLOAT-FREE DRU No Damage to the DCU or Bracket 1. Confirm that the capsule of the float-free DRU is seated in its bracket. Capsule Bracket Float-free DRU (cover removed) 2. Make the connections shown below. Remote alarm panel (RAP) J309 (RAP) port: Connect the remote alarm panel (RAP).
3. DATA EXTRACTION FROM FLOAT-FREE DRU Damage to the DCU, No Damage to the Bracket When the DCU is damaged, or you remove the float-free DRU to extract the data on shore, pre- pare the external power supply (24 VDC) for the float-free DRU. If you remove the float-free DRU, removal of the junction box is also required.
3. DATA EXTRACTION FROM FLOAT-FREE DRU Damage to the DCU and Bracket of the DRU When both the DCU and the bracket of the DRU are damaged, data can not be extracted by the normal method. First remove the storage board in the storage module, then connect a A/Micro B USB cable to extract the data.
Page 17
3. DATA EXTRACTION FROM FLOAT-FREE DRU 3) Remove the storage board. Note: Do not remove the SSD board from the storage board. SSD board Micro USB port Storage board 2. Using a A/Micro B USB cable, connect the storage board to the PC. 3.
Page 18
3. DATA EXTRACTION FROM FLOAT-FREE DRU 4) Enter the username and password. • [Username]: admin • [Passward]: Contact your dealer. 5) Select [Networking] and [Network Configuration] from the menu at the left of the display. 6) Select [Network Interfaces]. 7) Select [eth0]. 8) Change the IP address ([IPv4 address]) to “10.0.0.151“, then click the [Save] button.
DATA EXTRACTION FROM DCU To extract the data from the DCU, connect the PC to the J502 port (DATA) with the LAN cable (supplied). Then start the Live Player V5 on the PC to extract the data. For how to extract the data, see chapter 5. J502 port (DATA) LAN cable...
DATA EXTRACTION/REPLAY Data Extraction with Live Player V5 Notes on extraction • Free space of more than 30 GB is required in the C drive of the PC to create a temporary file for the data extraction. • The data recording more than 13 hours cannot be extracted at once. •...
Page 21
5. DATA EXTRACTION/REPLAY 3. Select each one of the following options from the drop-down list. • For data extraction from the DCU: [Long Term Device(LAN)] • For data extraction from the fixed DRU: [Fixed DRU]* • For data extraction from the float-free DRU: [Float DRU]* •...
Page 22
5. DATA EXTRACTION/REPLAY 8. Click [Extract] in the [Tool] menu to show the [Extraction] window. 9. Specify the extraction data by each one of the following methods. • Select the track. • Select date and period. How to select the track: 1) Activate the [Track Selection] radio button, then check the track you want to extract.
Page 23
5. DATA EXTRACTION/REPLAY How to select date and period: 1) Activate the [Direct Selection] radio button. 2) Select the target date and period to extract. 10. Click the [Select...] button and specify saving location in the [Folder/File Name] field. 11. Click the [Start] button. The confirmation message that indicates the data size appears.
5. DATA EXTRACTION/REPLAY How to Replay the Data Copied into the PC Note: When you adjust the seek bar to control position of playback, the audio data may not be replayed correctly. In this case, adjust the seek bar to move the position of playback forward or backward.