2. SOFTWARE CONFIGURATION
2.10
JB
Connect the Junction Box to the DCU before turning on the system. The [JB] tab
functions to set up the Junction Box 1.
How to set up the Junction Box
1. Click the [JB] tab.
2. Select a Junction Box from the [Information] window.
3. Set up the Junction Box from the [Setting] window.
4. Click the [Set] button. (Be sure to do this before moving to another channel).
5. Click the [Check] button to perform an inspection on all channels. In the
[Information] window check column, either [OK] or [NG] (No Good) is displayed.
When using Config Manager with Tabs:
1. From the [Maintenance] menu, click [VDR Config Management].
2. Click the [Upload] button to record to VDR memory.
3. Click the [Write] buttons to record to DRU, Long Term Device, and CF.
Description of the items in the Setting window
[Active] : Put check in check box to make channel active.
[No] : Display Junction Box number.
[IP Address] : Display IP address of Junction Box, acquired by VDR.
[MAC Address] : Display MAC address of Junction Box, acquired by VDR.
[Check] : Enable and disable equipment check.
[Note]: Enter remarks. (Entry optional.)