Remote Control; Log Set Installation - Jøtul Lillehammer Installation And Operation Instructions Manual

Direct vent gas stove pilot-on demand ignition
Table of Contents

Advertisement

139955-01 GF 200 DVII MV / Sept. 2019
Optional Wall Thermostat or

Remote Control

Use only a 750 millivolt DC two-wire circuit thermostat
with this appliance. The thermostat should be placed
in the same room as the heater, typically 5 feet off the
floor. Avoid drafty areas or any area that may affect the
accuracy of the thermostat.
The thermostat should be connected using a
minimum of 16 gauge wire with a maximum length of 35
feet of wire.
Connect the two thermostat wire leads to the
two lower terminals on the terminal block located
directly to the right of the valve. Do not overtighten the
connections. IT IS NOT NECESSARY TO DISCONNECT ANY
OTHER WIRES. See Fig. 27.
For thermostatic operation, the On/Off/T-Stat switch
on the back of the stove must be in the T-stat position,
and the pilot light must be running, as it is the power
source for the thermostat.
At the thermostat, the two wires should be
connected to the two connection screws on the
thermostat base plate per the manufacturer's
instructions.
Remote Control
When using a remote, the remote receiver should
be wired to the terminal block the same way the
thermostat would be. See the instructions above.
Follow the operating instructions included with the
Remote Control unit.
CAUTION:
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN
SERVICING THE CONTROLS. WIRING ERRORS CAN CAUSE
IMPROPER OR DANGEROUS OPERATION. ALWAYS VERIFY
PROPER OPERATION AFTER SERVICING THE APPLIANCE.
THERMOPILE
TH
TP
TH
TP
VALVE
Figure 27. Accessory wiring diagram.
20
ROCKER
SWITCH
ON
OFF
STAT
OPTIONAL
THERMOSTAT
or
REMOTE
CONTROL
TERMINAL
BLOCK

Log Set Installation

NOTE: Install the optional Brick Kit, if appropriate, before
installing the Log Set. See page 30.
The Log Set and Ember Stones are packaged in foam
inside the firebox. Handle these parts with gloves to avoid
skin irritation.
1. Assemble the Left and Right Rear Logs as shown in
fig 28. First engage the halves together, and then
engage the pins on the burner skirt with the adjacent
holes in the underside of the logs.
2. Locate the Middle Log as shown in fig. 29.
3. Also included is a bag of ember stones that simulate
glowing coals when the burner is operating. These
should be spread thinly over the burner plate.
NOTE: Keep the ember stones 1/4" away from the edge
of the Burner Skirt and Pilot Assembly. See fig. 29.
All the ember stones do not have to be used.
Figure 28.
Install
Rear Log.
KEEP EMBER STONES FROM
OBSTRUCTING PILOT AREA.
Figure 29. Middle Log and ember stones in place.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gf 200 dv ii mvGf 200 dv ii mv lillehammer

Table of Contents