Optional Blower Installation - Jøtul GF 300 DV Installation And Operation Instructions Manual

Jotul gf 300 dv allagash direct vent gas stove
Table of Contents

Advertisement

Optional Blower # 156000
Read these instructions before beginning the installation.
1. Unpack and check the contents of the blower kit.
The kit includes two Air Deflectors and two #7 x 1/2"
screws that will not be used with the GF 300 DV
Allagash stove. Contact your dealer if any damage is
evident or parts are missing. See fig. 42.
2. Install the Snapstat by sliding it all the way into the
slot in the bottom of the Snapstat Bracket as shown
in fig. 43.
3. Attach the Snapstat Bracket to the studs located in
the middle of the firebox floor using the two M6
hex nuts and a 10 mm wrench. See fig. 43.
4. Attach the Blower Bracket to the stove using the
two M6 flange head hex bolts as shown in fig. 43.
5. Install the Blower with the duct openings oriented
up and to the rear. See fig. 44. Feed the snapstat
wire harness through the bracket opening and
secure the blower to the bracket with the
wingscrew. Route the controls wire harness over to
the female quickconnector already installed in the
stove.
6. Attach either Snapstat wire connector to either
Snapstat terminal. See fig. 44.
7. Connect the male Control Switch connector to the
female control switch wire harness already installed
in the stove. See fig. 44.
8. Connect power cord to outlet.
Do not connect blower to power supply until
all wire connections have been made.
This blower must be electrically grounded in
accordance with local codes or, in the ab-
sence of local codes, with the current ANSI/
NFPA 70, National Electrical Code or CSA
C22.1-Canadian Electrical Code.
This unit is supplied with a three-prong
(grounding) plug for protection against
shock hazard and should be plugged directly
into a properly grounded three-prong
receptacle. DO NOT CUT OR REMOVE THE
GROUNDING PRONG FROM THE PLUG.
Always disconect the power supply when
performing any service on the fireplace
insert.
1
Contents
1. Blower
2. Mounting Bracket
3. Snapstat Wire Harness
4. Control Switch Wire Harness
5. Snapstat
6. Snapstat Bracket
7. M6 x 1 x 20 Flange Nuts (2)
8. M6 x 12 Hex Head Flange Bolts
9. M6 x 12 Wingscrew
Figure 42. 156000 Blower Kit Components used for
GF 300 DV Allagash.
Hex Head
Flange Bolts
Blower Bracket
Figure 43 . Attach Snapstat and Blower Brackets.
6
5
3
8
4
Tools Required
• 10 mm wrench
• short phillips
screwdriver
• Safety goggles
• Work gloves
Snapstat
Bracket
Hex Head
Flange Nuts
7
2