7145 series Field Service Ver.4.0 Mar. 2004
Classification Warning
code
Network
N73
abnormalities
N74
N75
N76
N77
N80
N81
N82
N83
N84
N86
Causes
LDAP search error
The results of retrieval are in
excess of the maximum number.
LDAP search error
The LDAP server has been set the
Referral setting and cannot access
to the reference data.
LDAP connection/search error
A time-out occurred due to the
LDAP server being not found.
LDAP connection error
Cannot connect to the LDAP
server. (At serch operation)
LDAP parameter abnormality
No bind can be made successfully
due to parameter abnormality.
Network scan operation abnormality
The IP address of the FTP
parameter is abnormal.
The length of the file name is in
excess of the upper limit of 32
bytes.
The descriptor is illegal.
Network scan operation abnormality
The server is not started.
The port number is wrong.
The IP address is wrong.
The proxy server connection is
abnormal.
Network scan operation abnormality
The FTP server was down
while data was being sent.
Network scan operation abnormality
The network connection route is
abnormal.
Network scan operation abnormality
The log-in name and the password
are illegal.
Network scan operation abnormality
The network connection route
is abnormal.
The server supporting the
"Passive" mode has not been
set to "Passive."
Resulting
operation
Stop the LDAP
function
Stop the Net-
work scan func-
tion (FTP)
Stop the Net-
work scan func-
tion (FTP)
4-71
ERROR CODE LIST
Estimated abnormal parts
SCB (System control board)
Network section
SCB (System control board)
Network section
Network cable
SCB (System control board)
Network section
SCB (System control board)
Network section
Network cable
SCB (System control board)
Network section
SCB (System control board)
Network section
Network cable
3