ERROR CODE LIST
Classification Warning
code
Network
N60
abnormalities
N61
N62
N63
N64
N65
N66
N70
N71
N72
3
Causes
Network scan operation abnormality
The SMTP server connection
is abnormal.
The length of time set for "POP
before SMTP" is longer than
the retention time approved for
the POP server.
Network scan operation abnormality
An attached file in excess of
the maximum size for the
SMTP server has been sent.
The SMTP server was down
while an attached file was
being sent.
Network scan operation abnormality
A reset operation has been
made while in the network
scan operation.
Network scan operation abnormality
The size of an attached file is
in excess of the maximum size
for the SMTP server.
There is not sufficient free
space left in the SMTP server.
Network scan operation abnormality
Shortage of the buffer.
Network scan operation abnormality
The EPNET Mail has been in con-
tention with other mails for send-
ing.
Network scan operation abnormality
The "From" address has been
specified in the domain that is not
allowed for the SMTP server.
LDAP connection error
The MIO has not completed the
preceding transaction.
LDAP connection/search error
A request for cancel has been
issued by the client.
LDAP search error
The route of retrieval has been
incorrectly specified.
7145 series Field Service Ver.4.0 Mar. 2004
Resulting
operation
Stop the Net-
work scan func-
tion (E-Mail)
Stop the LDAP
function
4-70
Estimated abnormal parts
SCB (System control board)
Network section
JOB
SCB (System control board)
Network section