Summary of Contents for Rinnai Symmetry RDV3611

  • Page 1 Installation guide Symmetry RDV3611...
  • Page 2 Important: The Symmetry RDV3611 is recommended for a new build installation into a false (mock) chimney. It is not suitable for retrofitting into an existing masonry fireplace. Appliance, including flue, is installed after framing and before cladding. Rinnai strongly recommend appliance is fully tested before any cladding material are applied.
  • Page 3: Table Of Contents

    TV installation above a fireplace Installation guide overview Building the frame Electrical connection Bracket installation Fixing the unit to the frame Flue installation - Rinnai flue kits RDV3611 horizontal flue kits RDV3611 flue components Flue guidelines RDV3611 flueing options Gas connection...
  • Page 4: Specification

    Flue Temperature control Inner: 100 mm, outer: 170 mm. Thermostatic, temperature control Appliance must be installed with a range 7-32 °C. Rinnai applied flue system. 4 | RDV3611 Installation Manual: 11156-A 01-12...
  • Page 5: Location

    Location The main points governing location are flueing and warm air distribution. The heater must not be installed where curtains or other combustible materials could come into contact with the appliance. In some cases curtains may need restraining. Enclosure dimensions The heater must be positioned on a flat level surface.
  • Page 6: Clearances

    Clearances The appliance must not be installed where curtains or other combustible materials could come into contact with the heater. In some case curtains may need restraining. The clearances listed below are minimum clearances unless otherwise stated. Due to the number of different sized Symmetry frames, all dimensions are taken from the To ceiling...
  • Page 7: Tv Installation Above A Fireplace

    If installing a flat screen TV above the fire, the main issue is heat. Heat from the fire, and heat from the flueing components that sit behind the TV—especially if recessed The Symmetry RDV3611 has a fan Directly Above Recessed...
  • Page 8 Symmetry RDV3611 Installation...
  • Page 9: Installation Guide Overview

    Installation guide overview This overview is intended to provide installation information at a high level. Further detail on each of the steps are provided in the following pages. Before installation Unpack the appliance and components, and check for damage. DO NOT install any damaged parts.
  • Page 10: Building The Frame

    Rinnai, part number 6765B. Bracket installation Install the four mounting brackets supplied onto the Symmetry RDV3611. The position of the brackets will depend on the cladding thickness, and type of installation (framed or frameless). The Symmetry RDV3611 can...
  • Page 11: Fixing The Unit To The Frame

    Fixing the unit to the frame The Symmetry RDV3611 comes pre-assembled with the burner already in position. For all installations, the unit MUST BE positioned on a level surface. 1. Position the unit inside the cavity. 2. Bend and secure the two metal standoffs supplied with the unit into position.
  • Page 12: Flue Installation: Rinnai Flue Kits

    Flue installation: Rinnai flue kits Rinnai Symmetry RDV3611 flue kits have been based on the flue configurations shown. If you have a combined vertical and horizontal flue configuration, you can order separate components to suit. Roof cowl (high wind) Flue pipe short (1 x 300 mm) or...
  • Page 13: Rdv3611 Horizontal Flue Kits

    RDV3611 horizontal flue kits The following diagram explains the components, dimensions (mm), and appropriate flue kits available for differing horizontal flue installations. Refer to the table below to calculate what flue pipe length and/or kit you may need. 325 - 440 435 - 550 90 º...
  • Page 14: Rdv3611 Flue Components

    RDV3611 flue components Flue elbow 90 ° Flue elbow 45 ° Flue pipes Code = R3643 Code = R3642 Codes 150 mm = R3630 Used to facilitate vertical and Offsets obstructions. Elbow 230 mm = R3631 horizontal flueing. Elbow swivels 360 ° at base. Angle 300 mm = R3632 swivels 360 °...
  • Page 15 Ø268 mm Elbow strap Roof cowl Horizontal flashing kit Code = R3644 Code = R3651 Code = R3646 Used to prevent excessive Aluminium flue terminal Flashing components used to weight in the flue elbow. required for all vertical join internal flue to the outside installations.
  • Page 16: Flue Guidelines

    Wall straps have been included in the The Rinnai Symmetry RDV3611 Rinnai Vertical Flue Kit to assist must be installed with an with this. Elbow straps are also approved Rinnai flue system.
  • Page 17: Rdv3611 Flueing Options

    RDV3611 flueing options Vertical termination with Vertical termination with 90 ° bends Horizontal termination with a 45 ° bends 90 ° bend Max. 1.2 m Max. 5.4m Max. 5.4 m Max. 5.4 m Restrictor position # 2 Restrictor position # 3 Restrictor position # 2 4.2 m 4.2 m...
  • Page 18: Gas Connection

    Gas connection The gas connection from the control valve is a ½ “ BSP male flare fitting. This connects straight into the gas control on the lower left hand side of the appliance. Gas pipe sizing must consider the gas input to this appliance, as well as other gas appliances in the premises.
  • Page 19: Flue Restrictor Installation

    Flue restrictor installation Different flue configurations require different positioning of the flue restrictor—refer to the RDV3611 flueing options page to determine what setting is required. The flue restrictor works by limiting the amount of air required for combustion. The higher the flue, the more the air is circulated.
  • Page 20: Log Set Installation

    The unit must NEVER be used with broken logs, or used with other burn media, except Rinnai Rockwool. Moulded rocks The rocks form an important part of the log set and must be positioned as shown on the following page.
  • Page 21 1. Carefully remove log set from packaging and fit the Front Base Left Log in the created gap. It should only fit one way. 2. Fit Front Base Right Log into position on the far right of the burner base. 3.
  • Page 22: Test Pressures

    Test pressures To check and set the burner pressures Outlet test point Inlet test point 1. Turn on the gas and power supply to the unit. 2. Refer to the data plate for applicable test point pressures. Gas outlet 3. The test point is on the gas control valve.
  • Page 23: Flame Pattern

    If the appliance cannot be made to perform correctly please contact Rinnai. RDV3611 Installation Manual: 11156-A 01-12 | 23...
  • Page 24: Cladding

    Cladding Cladding MUST NOT extend lower than the cladding support bracket. WARNING Enclosure framework 1120 Cladding Cladding support bracket Front of heater Cladding Cladding support bracket Front of heater When installing the cladding, ensure it is installed up to the flange and not over it. Any overhang will affect performance of the appliance and cause an unsafe situation.
  • Page 25: Fitting The Frames & Dress Guard

    Fitting the frames & dress guard Before fitting the frames and/or dress guard, ensure the glass front is secured in place. It is critical when fitting the glass front that you double check that it is not scratched or WARNING damaged in any way, and that you have checked the gasket.
  • Page 26: Wiring Diagram

    Wiring diagram (11652-A) AC 230V -240V 50 Hz (BROWN) (BROWN) (BLACK) (BLACK) (RED) (RED) (BROWN) (BROWN) (WHITE) (BLUE) (RED) (YELLOW) CABLE CAT 5 26 | RDV3611 Installation Manual: 11156-A 01-12...
  • Page 28 For more information call: Consumers: 0800 RINNAI (0800 746 624) Rinnai.co.nz Experience our innovation Installers: 0800 TO RINNAI (0800 86 746 624)