2. Installation
They can be specified also via Web Image Monitor, from Device
Management>Configuration>Device Setting>Auto Firmware Update. (However, "Auto
Firmware Update" appears on Web Image Monitor only if the ARFU function is set to "ON".)
3.
Set SP5-886-111(AutoUpdateSetting) to "1(ON)"
• To download the firmware only using SFU, and not by ARFU, specify the settings as follows:
- SP5-886-111(AutoUpdateSetting) to "0 (OFF)"
- Set SP5-886-115 (SfuAutoDownloadSetting) to "1 (ON)"
4.
When setting the prohibited day, time and so on of the auto firmware update, set them
with following SPs, or Web Image Monitor.
• SP5-886-112 (AutoUpdateProhibitTermSetting)
0: OFF, 1: ON (Default )
• SP5-886-113 (AutoUpdateProhibitStartHour)
Default: 9
• SP5-886-114 (AutoUpdateProhibitEndHour)
Default: 17
• SP5-886-120 (AutoUpdateProhibitDayOfWeekSetting)
Default: 0x00
Set the bits for the days of the week to prohibit updating.
Prohibited (Monday - Sunday): Bit 7
Monday: bit 6
Tuesday: bit 5
Wednesday: bit 4
Thursday: bit 3
Friday: bit 2
Saturday: bit 1
Sunday: bit 0
e.g.) Prohibited on Mon., Fri., Sat., and Sun.: 0x47 (01000111)
5.
Use the machine with its main power on and connected to the Internet.
Specifying the Time and Day of the Week to Prohibit Updating via Web Image Monitor
1.
Start the Web Image Monitor.
2.
Log in as the machine administrator.
96