CHAPTER 7 TROUBLESHOOTING
2.
Microswitches
Name
Microswitches
7-12
MS9
Figure 7-202
Notation
MS1
Detects the state (open) of the front door and the upper door
MS2
Detects the state (closed) of the swing guide 1
MS3
Detects the safety range
MS4
Detects the state (closed) of the shutter
MS6
Detects the state (closed) of the swing guide 2
MS7
Detects the cartridge (inside stapler)
MS8
Detects the presence/absence of staples (inside stapler)
MS9
Detects the tray coming close
Table 7-202
MS2
MS6
MS3
MS1
MS4
MS7
MS8
Function