Sharp AR-F15 Service Manual page 181

Digital copier/printer/ multifunctional system option finisher/punch module
Table of Contents

Advertisement

4.
Removing the Stitcher Mount Unit
1) Remove the front inside cover (see II-A-3).
2) Remove the E-ring [1], and remove the roll
[2] and the shaft [3].
3) Pull out the stitcher mount unit [4] to the
front.
5.
Adjusting the Stitcher Position
1) Remove the front lower door (see II-A-1).
2) Remove the front inside cover (see II-A-3).
3) Open the front door assembly.
4) Pull out the stitcher mount unit to the front,
then pull out the stitcher towards you and
then pull the stitcher down.
5) Remove the three screws [1], and remove
the stitcher mount unit cover [2].
CHAPTER 5 MECHANICAL CONSTRUCTION
Figure 5-223
[4]
Figure 5-224
[2]
Figure 5-225
[2]
[1]
[3]
[1]
5-25