0 - 12

Source of the Operation Command

Settings
This parameter is used to set the source of the operation command.
0 - 13

Stop Method

Settings
The parameter determines how the motor is stopped when the AC motor drive receives a valid
stop command or detects External Fault.
1. Ramp:
2. Coast:
3. The motor stop method is usually determined by the characteristics of the motor load and
how frequently it is stopped.
(1)
It is recommended to use "ramp to stop" for safety of personnel or to prevent
material from being wasted in applications where the motor has to stop after the
Revision Jan. 2007, MDE2, SW V1.05
00
Digital keypad
01
External terminals. Keypad STOP enabled.
02
External terminals. Keypad STOP disabled.
03
RS-485 serial communication (RJ-11). Keypad STOP enabled.
04
RS-485 serial communication (RJ-11). Keypad STOP disabled.
00
Ramp to stop
01
Coast to stop
02
STOP: ramp to stop
03
STOP: coast to stop
the AC motor drive decelerates to Minimum Output Frequency (Pr.1-05)
according to the deceleration time and then stops.
the AC motor drive stops the output instantly upon command, and the motor
free runs until it comes to a complete standstill.
Chapter 5 Parameters|VFD-M-D Series
Factory Setting: 00
Factory Setting: 00
E.F.: coast to stop
E.F.: coast to stop
E.F.: ramp to stop
E.F.: ramp to stop