Chapter 5 Parameters|VFD-M-D Series
Parameter
Explanation
5-34
Reset after re-
open/re-close

Group 6 Digital Output Parameters

Parameter
Explanation
Multi-function Output
6-00
(RA1, RB1, RC1)
Multi-function Output
6-01
(RA2, RC2)
Multi-function Output
6-02
MO1
(communication)
Multi-function Output
6-03
MO2
(communication)
Multi-function Output
6-04
MO3
(communication)
Multi-function Output
6-05
MO4
(communication)
5-10
Settings
Bit0=0: Disable to detect the incorrect
open/close limit
Bit0=1: Enable to detect the incorrect
open/close limit
Bit1=0: Enable to re-open when door close
error
Bit1=0: Disable to re-open when door close
error
Bit2=0 Enable S-Curve when re-open
Bit2=1 Disable S-Curve when re-open
Settings
00: No function
01: AC drive operational
02: Master frequency attained
03: Over-Torque Detection
04: Low-Voltage Indication
05: Operation Mode Indication
06: Fault Indication
07: Warning Indication
08: Demo Indication
09: A Step Completed
10: A Demo Completed
11: Forced Stop Indication
12: Heat Sink Overheat Warning
13: AC Drive Ready
14: Emergency Stop
15: Soft Braking Signal
16: Zero Speed Output Signal
17: Feedback Signal Error
18: Position Detection 1
19: Position Detection 2
20: Position Detection 3
21: The signal outputs when it is in close
completed position
Factory
Setting
00
Factory
Setting
00
00
00
00
00
00
Revision Jan. 2007, MDE2, SW V1.05