Summary Of Parameter Settings; Group 0 User Parameters - Delta VFD-M-D series User Manual

Specific ac motor drives for the elevator door
Table of Contents

Advertisement

Chapter 5 Parameters|VFD-M-D Series

5.1 Summary of Parameter Settings

: The parameter can be set during operation.

Group 0 User Parameters

Parameter
Explanation
0-00
Identity Code of the
AC motor drive
0-01
Rated Current
Display of the AC
motor drive
0-02
Parameter Reset
Start-up Display
0-03
Selection
Content of Multi
0-04
Function Display
User-Defined
0-05
Coefficient K
0-06
Software Version
0-07
Password Input
0-08
Password Set
0-09
Door Control Mode
5-2
Settings
Read-only
Read-only
08: Keypad lock
09: All parameters are reset to factory settings
(50Hz, 220V)
10: All parameters are reset to factory settings
(60Hz, 220V)
00: Display the frequency command value (F)
01: Display the actual output frequency (H)
02: Display the content of user-defined unit (U)
03: Multifunction display, see Pr.0-04
04: FWD/REV command
00: Display output current (A)
01: Display the pulses
02: Display the walking distance and step
speed (1.tt)
03: Display DC-BUS voltage (
04: Display output voltage (E)
05: Output power factor angle (n)
06: Display output power (P)
07: Display actual motor speed
08: Display the estimated value of torque as it
relates to current (t)
09: Display PG numbers/10ms (G)
10: Display the temperature of heat sink (°C)
11: Display external input terminal status (I.)
12: Display external output terminal status (o.)
13: Display communication address (d.)
0.01 to 160.0
Read-only
00 to 9999
00 to 9999
00: Distance control mode 1
01: Distance control mode 2
02: Multi-step control mode 1
03: Multi-step control mode 2
04: Multi-step control mode 3
05: Multi-step control mode 4
Factory
Setting
)
u
Revision Jan. 2007, MDE2, SW V1.05
Customer
##
#.#
00
00
00
1.00
#.##
00
00
00

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents