Door Control Mode - Delta VFD-M-D series User Manual

Specific ac motor drives for the elevator door
Table of Contents

Advertisement

Chapter 5 Parameters|VFD-M-D Series
Displays 00 when
entering correct
password into
Pr.0-07.
0 - 09

Door Control Mode

Settings
This parameter is used to select the control mode of AC motor drives. Refer to the following
explanation for detail.
00 Distance control mode 1
The drive is controlled by sensorless control. It should be set the Pr.2-11~Pr.2-14 correctly. It
will store the door width in Pr.2-24 and Pr.2-25 by Auto-tuning. It operates the door for speed
switch and completed position by counting the PG pulses. In this mode, position function will
be executed whenever power again and operates with low speed to the 0% or 100% door
width by the operation direction.
5-20
0-08
Correct Password
0-08
Displays 00 when
entering correct
password into
Pr.0-07.
00
Distance control mode 1
01
Distance control mode 2
02
Multi-step control mode 1
03
Multi-step control mode 2
04
Multi-step control mode 3
05
Multi-step control mode 4
0-07
Incorrect Password
END
3 chances to enter the correct
password.
1st time displays "01" if
password is incorrect.
2nd time displays "02", if
password is incorrect.
3rd time displays "Pcde"
(blinking)
If the password was entered
incorrectly after three tries,
the keypad will be locked.
Turn the power OFF/ON to
re-enter the password.
END
0-07
Factory Setting: 00
Revision Jan. 2007, MDE2, SW V1.05

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents