Installation
Position the top at the front (Fig. 36, [1]) between the
side walls so that the cut-out engages (Fig. 36, [3])
above the cross support bracket.
Secure the top with one self-tapping screw on each
(Fig. 36, [2]) of the side walls.
Install the control unit, position the capillary tubes
and the sensor well and insert the sensors into the
wells, before any other hood components are
positioned (see chapter 2.8 "Control unit", page 30).
Position the rear hood (Fig. 37, [1]) between the side
walls, so that the cut-out engages (Fig. 37, [2]) above
the cross support bracket.
Push the plinth rails (front and back) (Fig. 38, [2]) on the
lower side wall edge and secure on their sides with one
self-tapping screw each (Fig. 38, [1] & [3]).
28
Logano GE315 - We reserve the right to make any changes due to technical modifications
1
Fig. 36 Installation of the front hood
1
1
2
Fig. 37 Installation of the rear hood
3
2
Fig. 38 Installation of the front plinth rail