ETHERNET/C
The Programming Sections described in this document can be viewed at the SCW
LCD. To start programming enter: [*][8][installer code] [851][# # # ], Where # # # is
the 3 digit Section number referenced in this section. The Programming Worksheets
at the end of this document can be used to record the new values when program-
ming changes have been made from the default values.
Programming Sections are accessed through Connect24. Installers may review/
record programming Options at the panel.
NOTE: Ethernet/Cellular Programming Sections accessed through the panel are for
display purposes only. Configuration changes must be done using Connect24.
[001] Ethernet IP Address
Default (000.000.000.000)
Enter the IP address of the Communicator. Ensure that the IP address is unique to
your Communicator on the local network. Format is 4 fields, each field is a 3 digit dec-
imal number. Valid range: 000-255. If an IP address is programmed in this Section,
the unit will operate with Static IP (DHCP disabled). Sections [002] and [003] must
also be programmed when using Static IP addresses.
NOTE: Default for this Section is Dynamic Host Configuration Protocol (DHCP)
enabled. When enabled, the DHCP Server will set values for: IP Address
[001], Subnet Mask [002], and Gateway [003]. Programming an IP address in
this Section will disable DHCP (Static IP).
[002] Ethernet IP Subnet Mask
Default (255.255.255.000)
Enter the Ethernet IP Subnet Mask of the Communicator. Format is 4 fields, each
field is 3 digits. Valid range: 000-255.
NOTE: If DHCP is enabled, the DHCP Server will assign the subnet mask for this
Section and the programmed value will be ignored.
[003] Ethernet Gateway IP Address
Default (000.000.000.000)
Enter the Ethernet Gateway IP address of the Communicator. The gateway IP
address is required when a router is used on the local network to reach the
destination IP address specified in Section [001]. Format is 4 fields, each field is a 3
digit decimal number. Valid range: 000-255.
NOTE: If DHCP is enabled, the DHCP Server will assign the Gateway IP address for
this Section and the programmed value will be ignored.
[004] Receiver Supervision Interval
Default (0087/135)
When receiver supervision is enabled (ON) in Section [005] Toggle Option [3], the unit
sends heartbeats to Ethernet Receiver 1 or Cellular Receiver 1 to test the
communications path. Use this Section to set the interval time (in seconds) when
heartbeats will be sent to the receivers. Valid range 000A-FFFF seconds. If the
programmed value is less than (000A/10) seconds, supervision is disabled.
• Receiver Window: This is the supervision timeout that must be configured at the
central station receiver.
• Recommended Values: This is the recommended heartbeat interval that should
be programmed into the Communicator.
• For ULC installations, the Daily test transmission must be enabled over each
available communication channel Sections [125] and [225]. When programming
with Connect24, the recommended intervals will be programmed automatically
when the required window is selected.
P
ELLULAR
ROGRAMMING
S
O
YSTEM
PTIONS
16