Sms Command And Control Functions - DSC 3G2055 Installation Manual

Hspa/3g wireless alarm communicator ethernet/internet and hspa/3g dual-path alarm communicator
Hide thumbs Also See for 3G2055:
Table of Contents

Advertisement

If a valid telephone number is programmed, communications will use Public Switched
Telephone Network (PSTN). Entering a 4 digit hexadecimal value for a telephone num-
ber will change the call routing to the Communicator, as determined by the number
programmed:
DCAAF:Internal (All Receivers). Signals will be routed depending on Section [851]
[006] programming.
DCBBF:Ethernet Receiver 1 (Primary). (Not available for 3G2055).
DCCCF:Ethernet Receiver 2 (Backup). (Not available for 3G2055).
DCDDF:Cellular Receiver 1 (Primary).
DCEEF:Cellular Receiver 2 (Backup).
NOTE: Add a single 'F' as a suffix to the 4 digit hex number to populate the unused
remainder of the 32 character field.
5. Panel Section [350]: If any of the phone numbers have been programmed as
DCAA, DCBB, DCCC, DCDD, or DCEE, panel Section [350] must be set to [04] if
SIA format or [03] if Contact ID (CID) format is used by control panel.
6. Panel Section [382]: Toggle Option [5], 'GS/IP Module Enabled', must be set to
ON.
7 . Panel Section [401]: Toggle Option [1] must be set to ON in order to perform panel
DLS session through Cellular or Ethernet data channel.
8. Panel section [310], account code, auto syncs with the communicator account
code in section [021]. The panel account code ([*][8][installer code] [310]), will
overwrite the communicator account code section ([*][8][installer code] [850]
[021]) if programmed differently.
NOTE: Keep a record of the SIM card telephone number, it is required by users for
SMS Command and Control functions. (The number can be recorded in the
Programming Worksheets Section of this document, under Option [996]). Due to the
nature of the SIM card activation process with Cellular network carriers, it can take up
to 24 hours for SIM card activation to be complete.
SMS C
SMS Command and Control is available on SCW9055/57 panels. Users can send
SMS text messages from their mobile phone to the GSM phone number assigned to
their system. Commands are only accepted from telephone numbers that have been
programmed in Sections [311]-[318]. The system will reject messages sent from tele-
phone numbers that are not on the programmed list.
When the received SMS text matches a valid Section message, the function is per-
formed on the control panel. Text messages are not case sensitive and extra spaces
are ignored. A User Access Code may be required for some SMS messages.
The SMS Message format is in 3 parts: Command, Partition Label (or only the parti-
tion number), and Access Code.
If an Access Code is included in the message, it is sent to the control panel for valida-
tion, along with the requested function.
If the panel is configured to require an Access Code and the code is not sent (or
invalid) the panel will fail the function (unsuccessful).
If the panel fails the function, an SMS response message is sent to the user. The
SMS response will echo the command sensat, followed by the label "unsuccessful" .
(e.g., "night arm partition 2 1234 unsuccessful").
The partition label or partition number may be excluded from the SMS request in a
single partition system (e.g., disarm 9123).