Ethernet Receiver 1 Options - DSC 3G2055 Installation Manual

Hspa/3g wireless alarm communicator ethernet/internet and hspa/3g dual-path alarm communicator
Hide thumbs Also See for 3G2055:
Table of Contents

Advertisement

[036] Panel Firmware Update Successful
Default (FF);
Program 00 to disable this event transmission or FF to enable. This event will occur
when the panel firmware is updated successfully.
[037] Panel Firmware Update Fail
Default (FF);
Program 00 to disable this event transmission or FF to enable. This event will occur
when the panel firmware updated has failed.
Table 11: Firmware Upgrade Reporting Codes
Event
[033]Comm. FW
Update Begin
[034]Comm. FW
Update Successful
[035]Panel FW
Update Begin
[036]Panel FW
Update Successful
[037]Panel FW
Update Fail
[101] Ethernet Receiver 1 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between transmitters.
This account code is used when transmitting heartbeat signals to the central station
receiver. Signals received from the Panel will use the control panel account number.
Valid range: 0000000001-FFFFFFFFFE. Programming all 0 or all F will cause a Module
Configuration Trouble.
NOTE: If Ethernet Receiver 1 and Cellular Receiver 1 are programmed as the same
receiver (IP and port number are identical), Ethernet Receiver 1 account code
will be used.
[102] Ethernet Receiver 1 DNIS
Default (000000)
The Dialled Number Information Service (DNIS) is used in addition to the Account
Code to identify the Communicator module at the central station. Valid range:
000000 - 099999. Value is entered as a leading 0 followed by the 5 digit DNIS. Format
is Binary Coded Decimal (BCD).
NOTE: Each Ethernet/Cellular receiver must be programmed with a unique DNIS.
[103] Ethernet Receiver 1 Address
Default (127 .000.000.001)
The default address enables the Communicator to operate in Unattended Mode.
Unattended Mode is used when a receiver is not available and the unit is required to
perform DLS sessions. Typically used where the customer programs the control
panel daily due to access control and still wants to receive alarms without buying
extra hardware (receiver) or software.
SIA
SIA
Reporting
Identifier
Code
LB
00
LS
00
LB
00
LS
00
LU
00
E
THERNET
Contact
ID
Qualifier
1
3
1
3
1
R
1 O
ECEIVER
PTIONS
26
Contact
Contact
ID
ID
Event
Reporting
Code
Code
9
03
9
03
9
03
9
03
9
04
Contac
t ID
User/
Zone
002
002
003
003
003

Advertisement