7 . Apply AC power to panel, and replace the panel cover.
NOTE: If two way audio is enabled you will NOT be able to swap the SIM card with
another card.
The Communicator can be reset by cycling the power on the SCW.
E
STABLISHING A
The Communicator interfaces to the SCW through a keyed 16 pin Ribbon cable. See
Table 5 . The key prevents incorrect connection of the ribbon cable connector to the
SCW and Communicator. The pinout for the Ribbon cable is provided in the Table
below:
Table 5: Communicator Ribbon cable to SCW
Pin #
1
PC-Link TX
3
GND
5
Vref
7
AUD-OUT_N
9
AUD-IN_P
11
GND
13
GND
15
GND
Establishing a communication channel between the Communicator and the SCW is
critical to ensuring the desired operation of the two units. The following steps must
be completed during the on-site installation. Program the following to ensure that the
Communicator and the panel will work together as intended.
Initial Programming of Communicator and SCW
1. Enter [*][8][Installer Code] [Section Number] for panel programming. Record any
values that are modified from their default, in the appropriate Programming
Worksheets.
NOTE: When programming Toggle Options, the toggle is ON when the number is
displayed and OFF when the number is not dis played. (e.g., [1 - - - 5 - - - ], Toggle
Options 1 and 5 are ON, all others are OFF).
2. Panel Section [167] Cellular/Ethernet Interface Communications 'Wait for ACK':
Default value is: 060 seconds.
3. When the communicator is installed with the SCW panel, 4 telephone numbers
are available to backup one another. You can set up these 4 telephone numbers to
perform in one of two ways: Backup dialling or Alternate dialling.
a. Backup dialling: each of the 4 telephone numbers will make 5 dialling attempts
in turn, before an FTC trouble is displayed on the keypad.
b. Alternate dialling: each telephone number makes 1 dialling attempt before
moving on to the next number, cycling through each of the 4 numbers for a total
of 5 times each. If all 4 numbers fail the 5 attempts, an FTC trouble is displayed
on the keypad.
4. Panel Sections [301], [302], [303], and [305] can be configured as Primary
communication paths.
a. Panel Sections [302], [303], and [305] may also be configured for backup or
redundant communications by using Panel Section(s) [383] or [351] - [376].
Refer to the SCW panel Installation Manual for more information.
C
OMMUNICATOR
C
OMMUNICATION
Signal
2
4
6
8
10
12
14
16
R
ESET
C
HANNEL WITH THE
Pin #
PC-Link RX
Vref
GND
AUD-OUT_P
AUD-IN_N
SI
SO
Wall Tamper
12
SCW P
Signal
.
ANEL

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tl2553g