Subaru 1600 Service Manual page 673

Table of Contents

Advertisement

I
~ -----------+~~o
@
®
@
("~f-
i
~
'-------'<:'1
1
..;6)~O~@~J
Charger
Fig.
15-5
Charger-to-battery
connection
Battery
A9-005
The battery must be charged when
indicator shows "charging necessary"
and also engine does not start.
Perform charging for 5 hours or more
with a constant current of 6A.
At the condition of full charged, the
charging current is O.5A or less.
2) Quick charging
Quick charging is a method in which
the battery is charged in a short
period of time with a relatively large
current by using a quick charger.
, I,
I
I
~
I
",
ELECTRICAL SYSTEM
Since a large current flow raises elec-
trolyte temperature, the battery is
subject to damage if the large current
is used for prolonged time. For this
reason, the quick charging must be
carried out within a current range that
will not increase the electrolyte tem-
perature above 40°C (I 04° F).
It should be also remembered that the
quick charging is a temporary means
to bring battery voltage up to a fair
value and, as a rule, a battery should
be charged slowly with a low current.
NOTE:
a. Observe the items in NOTE in
1)
Normal charging.
b. The battery should not be charged
with lOA or more.
2. Fuse
The fuse box is located on the left side
underneath of the instrument panel.
The connection between each fuse and
main electrical units/devices is as
shown in the following illustration.
(Also refer to the wiring diagram at
the end of this manual.)
15-10
OM-867
Fig.
15-6
Fuse box
8~~~~~G~
~~B~~g~~
A25-549
Fig.
15-7
Fuse disposition