5 Installation
5-2-9

Mount the Industrial Monitor

Ensure the panel cut out is ready before beginning the mounting procedure.
Tools required: Torque screw driver with hexagon 2 mm bit.
The Industrial Monitor is equipped with 8 retractable mounting brackets on the back of the Monitor.
These brackets are used to fasten and secure the Monitor to the mounting surface.
Use the following procedure to mount the Monitor to the mounting surface:
1
Ensure all 8 retractable mounting brackets
the mounting brackets in the retracted position and hand tighten the allen bolt
2
Insert the Monitor into the mounting surface cut out so the bezel
face.
3
Loosen the allen bolts
The mounting brackets are spring loaded and will extend
4
Ensure all mounting brackets extend to overlap the mounting surface.
5
Tighten all mounting brackets to a torque of 0.6 N·m to maintain water and dust resistance.
Precautions for Safe Use
The mounting panel must be between 1.6 and 6.0 mm thick. Tighten the Mounting Brackets
evenly to a torque of 0.6 N·m to maintain water and dust resistance. If the tightening torque ex-
ceeds the specified value, or the tightening is not even, deformation of the front panel may oc-
cur. Additionally, make sure the panel is not dirty or warped and that it is strong enough to hold
the product.
5 - 16
A
are in the retracted position
1
of the mounting brackets.
2
. If required press
1
B
3
2
B
touches the mounting sur-
when loose.