Spa Fill Up Procedure - Jacuzzi J-585 Owner's Manual

J-500 collection
Table of Contents

Advertisement

Voltage:
Max. Current Draw:
Wattage:
Frequency:
Number of Wires:
In this configuration, the heater will operate while both jets pumps are
**
running. The Service 1 breaker will include connections for the heater
and transformer. The Service 2 breaker will have connections for all other
components. Note: 1x16A/20A is the factory setting.
*** In this configuration, the heater will operate while both jets pumps are
running. The Service 1 breaker will include the connection for the heater
and transformer. The Service 2 breaker (B) will have the connection for
jets pump 2. The Service 3 breaker (C) will have connections for jets pump
1 and all other components.
8.0

Spa Fill Up Procedure

For best results, read each step in its entirety before proceeding with this
procedure. Make sure all drains are closed before you begin, page 14.
1. Prepare The Spa For Filling
Clear all debris from the spa. (Although the spa shell has been
polished at the factory, you may want to treat it with a specially
formulated spa cleaner.) Consult your authorized Jacuzzi dealer for
additional information prior to filling spa.
Remove both ProClarity™ and ProClear™ Plus skimmer, polishing
filter lids and filters as illustrated in Section 13.1 (page 51).
2. Fill Spa
Place the end of your garden hose into empty skimming filter fitting
(on your left) as you stand next to the spa. Fill spa half way, then
place the garden hose into the opposite filter fitting (on your right)
while adding the remaining fill water.
CAUTION: TO DECREASE BUILD UP ON COMPONENTS AND
MINIMIZE ACRYLIC DAMAGE.
Never fill with water from a water softener. If your water is
extremely "hard," it is preferable to fill half-way with hard water and
the rest of the way with softened water. Water that is too soft can
be corrosive to metal components.
Export Models (50 Hz)
Dual Service Breakers
Service1/Service 2**
230 VAC
12A/17A
2,8kW/3,9 kW
50 Hz
5
Three Phase Service
Service1/Service 2/
Service 3***
230 VAC
12A/7A/10A
2,8kW/1,6kW/2,3kW
50 Hz
5
Page 17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

J-575

Table of Contents