Function Modules
Using a limit switch on the digital inputs, IP 267 can monitor the limits of a traversing range and stop
the traversing movement when the permissible range limit is exceeded. The activated input
"external stop" causes a calculated decelerating of the traversing movement. An emergency limit
switch can be installed at input "IS" (pulse inhibit). When this switch responds, the pulse output is
interrupted immediately.
For a reference point approach operation, an additional switch can be connected at input REF that
lies within the traversing zone. The reference point approach operation is also possible without this
switch.
Status LEDs provide you with the following information:
The IP 267 is configured
Pulse outputs during a positioning operation
Interruption of the positioning operation
There are four operating modes:
STOP
START FORWARDS
START BACKWARDS
NEUTRAL
Installation
1. Plug the IP 267 into a bus unit like any other I/O module (see chapter 3).
2. Insert the IP 267 module only into slots 0 to 7.
3. Connect the external switches to the DIs of the IP 267 via the terminal block.
4. Connect the stepper motor's power section to the 9-pin subminiature D female connector.
Addressing
The IP 267 is addressed like an analog module.
EWA 4NEB 812 6120-02
RDY
ACT
ABT
S5-100U
15-51