Function Modules
Reference
signal
Reference pulse
of the sensor
Reference
signal
Reference pulse
of the sensor
Sync
bit
Figure 15-19. Position of the Reference Point (SYNC Bit=1) during a Reversal of Direction
before Reaching the Reference Pulse in a Positive Direction
Example:
Transporting objects from point A to point B on a conveyor belt.
A rotary position encoder is used, together with a BERO proximity switch as reference
transmitter. The conveyor belt is marked at a definite point. As soon as this mark
comes within the range of the BERO, the BERO produces a reference signal.
Following the reference point approach, the enable input is set via a digital output module.
PS
CPU
DQ
Enable input
Reference input
Figure 15-20. Schematic of a Reference Point Approach Operation
EWA 4NEB 812 6120-02
Positive direction of traverse
Change of direction
Operation range
Rotary position
of reference
encoder
transmitter
Traversing path
Traversing range
Conveyor belt
Counting-up
direction
Mark
BERO as refer-
ence transmitter
S5100U
15-33