JRC JMA-5912-6 Instruction Manual page 434

Marine radar equipment
Table of Contents

Advertisement

2) SW12 setting (radar connection settings)
1
2
3
4
5
ON
OFF
3) SW13 (unused)
Note: Before the DIP switches of the interswitch circuit can be set, the interswitch breaker must be turned
off in order to ensure safety operation.
6
7
8
Radar connection settings
1
2
3
4
5
6
7
8
A-11
ON
No.1 display unit connected
OFF
No.1 display unit not connected
ON
No.1 scannerunit connected
OFF
No.1 scanner unit not connected
ON
No.2 display unit connected
OFF
No.2 display unit not connected
ON
No.2 scannerunit connected
OFF
No.2 scannerunit not connected
ON
No.3 display unit connected
OFF
No.3 display unit not connected
ON
No.3 scanner unit connected
OFF
No.3 scanner unit not connected
ON
No.4 display unit connected
OFF
No.4 display unit not connected
ON
No.4 scanner unit connected
OFF
No.4 scanner unit not connected